Verification of colilert methodology for determining and quantifying total coliforms and escherichia coli in a natural water matrix

dc.creatorArboleda-Baena, C. M.
dc.creatorArismendi-González, L. M.
dc.creatorSepúlveda-Sánchez, M.
dc.creatorRodríguez-López, M.
dc.creatorBetancur-Urán, J.
dc.date2016-06-30
dc.date.accessioned2023-06-29T13:33:34Z
dc.date.available2023-06-29T13:33:34Z
dc.descriptionDue to its selectivity and specificity, the Colilert methodology allows one to detect the sanitation indicators of water quality, total Coliforms and Escherichia coli. The aim of this study was to test the Colilert methodology applied to a natural water matrix. With a variation coefficient (CV) less than 6% and 7% for total Coliforms and E. coli respectively, this methodology has proven its repeatability. For both indicators, the middle accuracy was CV < 6% and percentages of recuperation were between 80–120%. The results proved that this method is precise, repeatable and accurate, according to the acceptance criteria entered in the Colombian Technique Guide GTC 84 from 2003; the Standard methods for the examination of water and the International Rule ISO/9308–2:2012. Thus, the method is suitable for detecting and quantifying total Coliforms and E. coli, while providing truthful and timely results for customers.en-US
dc.descriptionLa metodología Colilert permite la detección de los indicadores sanitarios de calidad del agua, Coliformes totales y Escherichia coli, debido a su selectividad y especificidad. El objetivo de este trabajo fue verificar la metodología Colilert en una matriz de agua natural. La repetibilidad de la metodología para Coliformes totales y E. coli obtuvo un coeficiente de variación (CV) menor al 6% y 7%, respectivamente. Para los dos indicadores la precisión intermedia tuvo un CV < 6% y los porcentajes de recuperación estuvieron entre 80-120%. Los resultados demostraron que el método es preciso, repetible y exacto según los criterios de aceptación consignados en la Guía Técnica Colombiana GTC 84:2003, el Standard methods for the examination of water y la Norma Internacional ISO/9308-2:2012. En consecuencia, el método es apropiado para la detección y cuantificación de Coliformes totales y E. coli y permite a los clientes acceder a resultados confiables y oportunos.es-ES
dc.formattext/html
dc.formatapplication/pdf
dc.identifierhttps://revistas.elpoli.edu.co/index.php/pol/article/view/882
dc.identifier.urihttps://repositorio.elpoli.edu.co/handle/123456789/966
dc.languagespa
dc.publisherPolitécnico Colombiano Jaime Isaza Cadavides-ES
dc.relationhttps://revistas.elpoli.edu.co/index.php/pol/article/view/882/1474
dc.relationhttps://revistas.elpoli.edu.co/index.php/pol/article/view/882/753
dc.sourceRevista Politécnica; Vol. 12 No. 22: January-June; 105-112en-US
dc.sourceRevista Politécnica; Vol. 12 Núm. 22: Enero-Junio, 2016; 105-112es-ES
dc.sourceRevista Politécnica; v. 12 n. 22: January-June; 105-112pt-BR
dc.source2256-5353
dc.source1900-2351
dc.subjectMetodología Colilertes-ES
dc.subjectindicadores de calidad microbiana del aguaes-ES
dc.subjectNúmero más probablees-ES
dc.subjectColilert methodologyen-US
dc.subjectmicrobial water quality indicatorsen-US
dc.subjectmost probable numberen-US
dc.titleVerification of colilert methodology for determining and quantifying total coliforms and escherichia coli in a natural water matrixen-US
dc.titleVerificación de la metodología colilert para la determinación y cuatificación de coliformes totales y escherichia coli en una matriz de agua naturales-ES
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
Files